EasyManua.ls Logo

ep RPL201 - Battery Type & Dimensions&Charging Time

ep RPL201
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REV. 09/2022
3C
Battery types & dimensions are as follows:
Tuck type battery type
Voltage/ Rated
capacity
Dimensions Charger
Charging
time
RPL201
Li-ion
24V/205Ah
550×190×500 50A/100A
More than
4.1h/2.05h
RPL201H
Li-ion
24V/205Ah
550×190×500 50A/100A
More than
4.1h/2.05h
RPL201/
RPL201H
Lead -acid
24V/280Ah
650×200×540
30A
9.5h
RPL251/
RPL301
Li-ion
24V/205Ah
550×190×500 100A More than 2h
RPL251/
RPL301
Lead -acid
24V/280Ah
621×281×625 30 9-10h
•Battery life will be shortened if the battery is used for a long time at low temperature or
stored.
•No charging below 0°C.
WARNING
1.1.3 Battery type & dimensions&Charging time
WARNING
Charger maximum input power 3.3KW . Please strictly implement the above data to prevent
equipment damage and accidental risks such as re.
WARNING
Damage to battery and charger!
The charger must be matched to the battery in terms of voltage and charging capacity!
Observe the correct combination of battery and charger to avoid overheating and re hazard.
Only use the charger that is suitable for the corresponding battery.