11
6. Protection
Protection
and recover
Condition
Phenomenon
Parameter
IPower-1*
IPower-2*
IPower-4*
Over voltage
protection
and recover
Input Voltage
Ui
Ui>16V
Ui>32V
Ui>64V
Output is OFF
Green indicator fast flashing
Buzzer sounds
Ui≤14.5V
Ui≤29V
Ui≤58V
Green indicator on solid
The output is on
Low voltage
protection
and recover
Input Voltage
Ui
Ui<10.8V
Ui<21.6V
Ui<43.2V
Output is OFF
Green indicator slowly flashing
Buzzer sounds
Ui≥12.5V
Ui≥25V
Ui≥50V
Green indicator on solid
The output is on
Over tem.
protection
and recover
Tem.(T)
Heat sink T80(IP1000 T75)
or Internal T60
Inverter turns OFF
Heat sink T≤70(IP1000 T65)
and Internal T≤50
Inverter turns ON