13
7. Troubleshooting
Faults
Possible reasons
Troubleshooting
Green indicator slowly flashing
Buzzer sounds
DC input under voltage
Measure the DC input voltage, if the voltage is lower
than 10.8/21.6/43.2V. Adjust the input voltage to
restore normally.
Green indicator fast flashing
Buzzer sounds
DC input over voltage
Measure the DC input voltage, if the voltage is
higher than 16/32/64V. Adjust the input voltage to
restore normally.
Red indicator slowly flashing
Buzzer sounds
Overload
Reduce the number of the AC load.
Restart the inverter.
Red indicator fast flashing
Buzzer sounds
Short circuit
Check carefully loads connection, clear the fault.
Restart the inverter.
Green and red indicator on
solid Buzzer sounds
Over temperature
When the heat sink temperature exceeds 80 or
the internal temperature exceeds 60, the inverter
will automatically stop output; When the heat sink
temperature below 70 and the internal
temperature below 50, the inverter will resume to
output.