EasyManua.ls Logo

Eppendorf 5430 - User Manual

Default Icon
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Register your instrument!
www.eppendorf.com/myeppendorf
Centrifuge 5430/5430 R
Operating manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Eppendorf 5430 and is the answer not in the manual?

Summary

Operating Instructions

Using this Manual

Guidance on how to use the manual effectively.

Danger Symbols and Levels

Explanation of safety symbols and their meanings.

Symbols Used

Defines symbols used within the manual for clarity.

Abbreviations Used

Lists and defines abbreviations used in the document.

Product Description

Main Illustration

Visual overview of the centrifuge with numbered components.

Delivery Package Contents

Lists items included in the centrifuge package.

Key Features

Highlights the centrifuge's capabilities and design.

Available Rotors

Details the different rotors compatible with the centrifuge.

RCF Display and Calculation

Explains how to display and calculate RCF values.

Safety

Intended Use and User Profile

Defines the product's intended application and operator qualifications.

Application Limits & Liability

Outlines restrictions on use and product liability clauses.

Accessory Service Life

Specifies the maximum service life for centrifuge accessories.

General Safety Warnings

Covers critical safety precautions for electrical hazards and health risks.

Handling Rotors and Tubes

Provides guidance on safe handling of rotors and tubes.

Aerosol-Tight Centrifugation

Details safety measures for aerosol-tight centrifugation.

Installation

Selecting the Location

Criteria for choosing a suitable installation site for the centrifuge.

Preparing and Installing the Instrument

Step-by-step instructions for unpacking and setting up the centrifuge.

Operation

Control Panel Overview

Identifies and explains the centrifuge's controls and display elements.

Menu Navigation and Settings

Guides users through the menu system and device configuration options.

Preparing for Centrifugation

Steps to prepare the centrifuge before starting a run.

Loading the Rotor

Instructions on how to properly load samples into the rotor.

Centrifugation Modes

Explains different centrifugation modes like FastTemp and continuous cooling.

Rotor Handling Procedures

Covers rotor removal, standby mode, and specific rotor instructions.

Operating Controls and Function

Device Menu Structure

Overview of the centrifuge's menu hierarchy and options.

Program Management

How to load, save, and delete centrifuge programs.

Other Menu Items

Details additional configurable menu options like soft ramp and key lock.

Settings Menu Options

Configuration of display, loudspeaker, volume, contrast, language, and standby.

Maintenance

Prepare Cleaning and Disinfection

General guidelines for cleaning and disinfecting the device and accessories.

Cleaning and Disinfection Procedures

Detailed steps for cleaning and disinfecting the centrifuge and its components.

Autoclaving and Rotor Care

Instructions for autoclaving rotors and caring for rotor lids and seals.

Additional Service for 5430 R

Specific maintenance and service instructions for the 5430 R model.

Glass Breakage Handling

Procedures to follow in case of glass breakage within the rotor chamber.

Fuse Replacement

Instructions for replacing fuses or understanding the protective switch.

Troubleshooting

General Errors and Remedies

Common errors and their corresponding solutions for the centrifuge.

Error Messages and Causes

Lists specific error messages, their causes, and remedies.

Emergency Lid Release

Procedure for manually opening the centrifuge lid in emergencies.

Transport, Storage, and Disposal

Transport Guidelines

Precautions and conditions for transporting the centrifuge.

Storage Conditions

Recommended conditions for storing the centrifuge.

Disposal Information

Guidance on the proper disposal of the device according to regulations.

Technical Data

Power Supply Specifications

Electrical ratings and connection details for the centrifuge.

Ambient Conditions

Environmental requirements for operating the centrifuge.

Weight and Dimensions

Physical specifications of the centrifuge models.

Application Parameters

Key operational parameters such as run time, speed, and load.

Rotor Speed and Temperature Data

Performance data for different rotors regarding speed and temperature.

Ordering Information

Centrifuge 5430 Models

Part numbers and descriptions for Centrifuge 5430 configurations.

Centrifuge 5430 R Models

Part numbers and descriptions for Centrifuge 5430 R configurations.

Rotors and Rotor Lids

Part numbers for various rotors and their corresponding lids.

Adapters for Tubes

Part numbers for adapters used with different tube types.

Other Accessories and Fuses

Part numbers for additional accessories, rotor keys, and fuses.

Declarations and Certificates

EC Conformity Declaration

Declaration of conformity with relevant EC directives and standards.

UL Compliance

Centrifuge 5430 UL Certification

UL certification details for the Centrifuge 5430 model.

UL Compliance

Centrifuge 5430 R UL Certification

UL certification details for the Centrifuge 5430R model.

Containment Testing Certificates

Rotor FA 45-30-11 Containment Test

Test report for containment of Rotor FA 45-30-11.

Rotor FA 45-24-11-HS Containment Test

Test report for containment of Rotor FA 45-24-11-HS.

Rotor FA 45-24-11-KIT Containment Test

Test report for containment of Rotor FA 45-24-11-KIT.

Rotor FA-45-48-11 Containment Test

Test report for containment of Rotor FA-45-48-11.

Rotor FA-45-30-11 Containment Test

Test report for containment of Rotor FA-45-30-11.

Rotor FA-45-24-11-Kit Containment Test

Test report for containment of Rotor FA-45-24-11-Kit.

Rotor FA-45-16-17 Containment Test

Test report for containment of Rotor FA-45-16-17.

Rotor S-24-11-AT Containment Test

Test report for containment of Rotor S-24-11-AT.

Annex

Menu Structure Overview

Visual representation of the centrifuge's menu structure.

Rotor F-35-6-30 Adapters

Details adapters for the F-35-6-30 rotor and their specifications.

Eppendorf 5430 Specifications

General IconGeneral
Maximum RCF30, 130 x g
Noise level<56 dB(A)
TypeMicrocentrifuge
Maximum Speed17, 500 rpm
Capacity48 x 1.5/2.0 mL
Temperature ControlYes
Power Supply230 V, 50/60 Hz
DisplayLCD
TimerYes, up to 99 h 59 min

Related product manuals