9) Time stamp (1/1028 sec to 1/128 sec reading) Example
Figure 46 Example flow (Time stamp (1/1024 sec, 1/128 sec reading) )
•To inactive time stamp EVIN pin detection.
Write Reg - 35h bit3~0 0000b
•Time Stamp Control 2 bit3~0 0
•To inactive RTC internal status detection time stamp
•Reading 2Fh makes time stamp triggering and
data (1/1024 sec) is stored to 20h.
•Reading 1/1024 sec data from 20h
•Reading 1/128 sec data from 21h.
•To activate Command Trigger