WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision A
Disassembly And Assembly Removing the Sensors 127
Confidential
4.6.5 Cover Open Sensor
1. Remove the Panel Unit. (p.69)
2. Remove the C.B.P. M3x10 screw that secures the Cover Open Sensor and remove
the Cover Open Sensor.
Figure 4-165. Removing the Cover Open Sensor
Align the four tabs and guide pin on the PE Sensor Holder with the
positioning holes on the Main Frame correctly so that there is no
gap between the PE Sensor Holder and the Main Frame.
Figure 4-164. Reinstalling the PE Sensor
Align the guide pins with the positioning holes shown in Figure
4-165.
Guide pins and
Positioning holes
Cover Open Sensor
1) C.B.P. M3x10
(6±1 kgf.cm)
高速行式打印机 http://www.lineprinter.com.cn/
_______________________________________________________________________________________
_______________________________________________________________________________________
打印机维修论坛 http://www.printerwhy.net/ 打印机驱动下载 http://www.printerwhy.com/