Appendix
67
Internal parameter settings
Internal parameter settings can be changed with the following:
•ENPC protocol: Epson provides a dedicated utility that makes miscellaneous setting with the
ENPC protocol.
•HTTP browser:An HTTP browser can make setting when connected to the module.
•arp commands and ping commands (Only IP address is settable.):
This function is available only when it has been enabled. The setting can be
made only from a host PC that supports both arp and ping commands and is
in the same segment as the module.
Article Parameters
Default
values
Utility Browser Status
sheet
print
View Setting View Setting
IP address 192.168.192.168 Yes Yes Yes Yes Yes
Subnet mask 255.255.255.0 Yes Yes Yes Yes Yes
Gateway address 0.0.0.0 Yes Yes Yes Yes Yes
DHCP Enable/Disable Disable Yes Yes Yes Yes Yes
APIPA Enable/Disable Disable Yes Yes Yes Yes Yes
Arp/ping IP setting Enable/Disable Enable Yes Yes Yes Yes No
Community name 1
(read-only)
Max. 16
characters
public Yes No Yes No Yes
Community name 2
(read-write)
Max. 16
characters
None Yes Yes Yes Yes Yes
IP Trap 1 Enable Enable/Disable Disable Yes Yes Yes Yes No
IP Trap 2 Enable Enable/Disable Disable Yes Yes Yes Yes No
Community name
(IP Trap #1)
Max. 16
characters
None Yes Yes Yes Yes No
Community name
(IP Trap #2)
Max. 16
characters
None Yes Yes Yes Yes No
IP trap #1 address None Yes Yes Yes Yes No
IP trap #2 address None Yes Yes Yes Yes No
Password None No Yes No Yes No
Physical layer
setting
Auto negotiation
/10Base-T Half
/10Base-T Full
/100Base-TX Half
/100Base-TX Full
Auto
negotiation
Yes Yes Yes Yes Yes
Hardware version Yes No Yes No Yes
Firmware version Yes No Yes No Yes
MAC address Yes No Yes No Yes