EasyManua.ls Logo

ESAB CaddyArc 150 - Mains power supply; OPERATION; Connections and control devices

ESAB CaddyArc 150
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-- 6 --
bh26d1e
5.3 Mains power supply
Make sure that the welding power source is connected to the correct supply voltage
and that it is protected by the correct fuse rating. The standards for the country in
question must be complied with as regards the mains cable area. A protective earth
connection must be made in accordance with regulations.
5.3.1 Recommend ed fuse sizes and minimum cable areas
CaddyArc 150
Mains vol tage 230 V ¦10 %, 1--phase
Mains frequency 50--60 Hz
Fuse (delayed--action)
100A 20% duty cycle
120A 35% duty cycle
150A 35% duty cycle
10 A
16 A
20 A*)
Mains cable, area 3x2.5mm
2
Welding cable, area 16 mm
2
*) Note! The installed plug is approved for max. 16A.
North American version: The mains cable is approved for maximun 18 A.
Note!The cable area and fuse rating above comply with Swedish regulations. Use
the welding power source in accordance with the relevant national regulations.
6OPERATION
6.1 Connections and control devices
1 Main power supply switch, 0 / 1 4 Connection for remote control
2 Mains cable 5 Welding cable connector (+)
3 Connection for return cable (--) 6 Control panel (see 6.2)
3 and 5 are used for welding current supply and return cable connection during MMA
welding
GB

Related product manuals