-- 2 9 --
doce
S Press .
The field “SET 6” is marked and parameter set 6 is active
Check before choosing
Suppose that while welding with parameter set 1 (“SET 1”) you decide to change to
parameter set 6 (“SET 6”) after first checking the parameters.
S Mark the field “SET 1 by pressing
+
.
S Press .
The field “SET 6” flashes.
S The new parameter set can be checked before being chosen by pressing
+
.
The complete row displaying the welding parameters flashes and displays the values
for parameter set 6 (“SET 6”), although parameter set 1 (“SET1”) remains in use
during the current welding cycle.
S Press .
The field “SET 6” is marked and parameter set 6 is active.
8 WELDING SETUP
8.1 General
In WELDING SETUP you can choose a variety of settings including start method,
welding direction, wire diameter and similar variables in order to carry out a specific
welding task. These settings cannot be changed during welding.
You can cancel any error message in the main m enu by pressing .
S Switch from the MAIN MENU to WELDING SETUP by pressing
.
The display will now show a number of variables in column A (see page 30) and the
relevant options in columns B and C. Other options can be scrolled forward one at a
time.
You can change row in column A.
S To change a setting, move from column A to columns B and C by pressing
.
S Scroll forward to the chosen option by pressing or
+
or type in
your own values for rows 3 and 4 (”Number of wires”).
S Return to column A to change row by pressing
+
.
S Jump to the next r ow by pressing .
After the last row you will return to row 1.