Fascia, Fuel Bed and Glass Care
15
Step 6:Replace in opposite order and test run heater.
Step 5: Clean the inside and outside of glass with normal glass
cleaning products. Use a CLEAN DRY cloth only. Stubborn marks
may be cleaned with a ceramic glass cleaner.
gas fires communicate both to and from the fire and
remote. This enables the remote to provide some basic fault finding
information that is useful in diagnosing faults with your gas supply or
flue.
Electronics
overtemp.
Troubleshooting
IB600 - Usually associated with a four sided fascia
being mounted too high resulting in an insufficient air
gap between the lower removable strip and the
bottom of the outer fascia.
All models - This fault may be indicative of the gas
regulator being set too high resulting in excess heat
build up. Note: This error has a permanent lock out
and will require the unit to be reset 10 minutes after
the initial error (Reset means turning the power to the
fire off "at the wall" then on again after a few
seconds).
NOTE: The remote will take a minute or two to receive and display
the error from the fire. Pressing the plus or minus keys will update the
remote
Continued...