F18 User Manual V1.0
- 54 -
4. System Option
Set system parameters to meet users demand as many as possible.
4.1 System parameters
1: 1 matching threshold value: The similarity of ID + fingerprint
verification and the enrolled template
1: N matching threshold value: The similarity of verification and the
enrolled template
Recommended matching threshold value:
FRR FAR
Matching threshold value
1:N 1:1
high low 45 25
middle middle 35 15
low high 25 10