E200PS Operation Manual
18
Parameter
Default
Range
Unit
Description
CP
0
0~99999
-
PP=0: this value is the
current work piece.
PP>0: this value is the
remain work piece.
STEP
XP
0.00
-9999.999~999
9.999
mm/inch
Program position of X-axis.
GP
0.00
0~99.99
mm/inch
Program position of G-axis.
DX
0.00
0~9999.999
mm/inch
Retract distance of X axle.
Cut Length
0
0~100
%
Actual time of the cut length
= Max time of the cut length
×Cut Length
Repeat Times
1
1~99
-
The repeat times in this
step.