E200PS Operation Manual
13
Parameter
Default
Range
Unit
Description
Cut Length
0
0~100
%
Actual time of the cut
length = Max time of the
cut length × Cut Length
Repeat Times
1
1~99
-
The repeat times in this
step.
Step 5 After finishing operation, you can accord the actual situation to run the device.
If you want to run the device from a certain step, press arrow key to switch that step
page, Press to run, the device enters RUN page.
If you want to run the device in in sequence, press back to PROGRAM page,
and then Press to run, the device enters RUN page.
----End
3.5 Manual
In general, operator wants to adjust the backgauge or the block, need to enter
MANUAL page to do relevant operation.
When the E200PS device is electrified, wait a few seconds into the SINGLE page (Default
page), press or enter MANUAL page, as shown in Figure 3-6.
[Operation Guide]:
Move the cursor and stay on the axis you want to adjust, press and hold , the
motor control this axis runs to the increment count direction slowly.
Move the cursor and stay on the axis you want to adjust, press and hold , the
motor control this axis runs to the decrement count direction slowly.
Move the cursor and stay on the axis you want to adjust, press and hold and
, the motor control this axis runs to the increment count direction quickly.
Move the cursor and stay on the axis you want to adjust, press and hold and
, the motor control this axis runs to the decrement count direction quickly.
MANUAL
: Unit:mm
X= 10.00
G= 10.00
Figure 3-6 The MANUAL page