3 Installation page 11
ELC X-Series-V1.5-06.18-GB subject to technical alterations
Position
(see
Fig. 8)
Cable
diameter
Connector
designation
Function
Connector
no. of pins
Connector
type eta
ID.:
Cable
length
(gasket to
connector)
Plug contact
1
6.8mm ±
5%
X806
Control
7
9535
130mm
ferrule, stripping
length 7mm
2
6.8mm ±
5%
X805
Control
11
9536
130mm
ferrule, stripping
length 7mm
3
7.5mm
±5%
X3
Bus out
(T-coupler)
3
9546
120mm
blank wire or
ferrule, stripping
length 9mm
4
7.5mm ±
5%
X1
Bus in
4
9545
120mm
blank wire or
ferrule, stripping
length 9mm
5
7.5mm ±
5%
X2
Bus out
4
9545
120mm
blank wire or
ferrule, stripping
length 9mm
6
9.8mm ±
5%
X806
Control
(alternative)
7
9535
130mm
ferrule, stripping
length 7mm
7
9.8mm ±
5%
X805
Control
(alternative)
11
9536
130mm
ferrule, stripping
length 7mm
8
13.5mm ±
5%
X600 (1, 3)
Lamp
output
2
-
155mm
blank wire or
ferrule stripping
length 15mm,
direct connection
on board
9
9.3mm ±
5%
X600 (1, 3)
Lamp
output
(alternative)
2
-
155mm
blank wire or
ferrule stripping
length 15mm,
direct connection
on board
10
5.4mm ±
5%
X600 (2)
PE
1
-
155mm
Blade receptacle
6.3mm, direct
connection on
board
X100 (1)
Mains input
PE
(alternativ)
1
9531
490mm
blank wire or
ferrule, stripping
length 18mm
11
5.4mm ±
5%
X100 (2)
Mains input
phase
(alternativ)
1
(9531)
490mm
blank wire or
ferrule, stripping
length 18mm
12
5.4mm ±
5%
X100 (4)
Mains input
phase
(alternativ)
1
(9531)
490mm
blank wire or
ferrule, stripping
length 18mm
13*
12.0mm ±
5%
X100
Mains input
(2 x phase, 2
x PE)
4
9531
490mm
blank wire or
ferrule, stripping
length 18mm
14.6mm ±
5%
Table 2: Cable connection parameters X12-X36