6.6
-
PARAMETERS
AND
FUNCTIONS
LAYOUT
(
Factory
default
-
pH)
FUNCTIONS
Setpoint
setting
Hysteresis
se
tting
Choice
of
the
type
of
intervention
Manual
or
proportional
intervention
selection
Definition
of
beginning
intervention
value
"A
UTO"
First
point
of
calibration
procedure
Second
point
of
calibration
procedure
Minimum
alarm
point
Maximum
alarm
point
Over-dosing
alarm
value
Selection
measures
to
control
(pH,
RX)
Chosen
thermal
selection
(°C
or
°F)
Temperature
compensation
selection
(manual
-
auto)
Delay
at
powering
on
Delay
exit
calibration
menu
DEFAULT
7,2
0,1
Acid
Manual
Setpoint
+
1pH
-------
-------
0,00
14,00
99:59
h:m
pH
°C
Manual
-
25°C
00:03
m:s
05:00
m:s
6.7
-
TYPICAL
CHARACTERISTICS
PARAMETER
Temperature
Max
current
relay
output
pH
measure
RX
(mV)
measure
VALUE
0÷40°C
6A
(resistive
load)
1A
(inductive
load)
14
(0,01
pH)
-1000
÷
+1400
1
mV)