EasyManua.ls Logo

Etatron DLX - Troubleshooting DLX pH-RX;MBB Series Pumps; Mechanical Faults Troubleshooting; Electrical Faults Troubleshooting

Default Icon
23 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
ENGLISH
9.0 -
TROUBLE-SHOOTING
COMMON TO
DLX
pH-RX/MBB
SERIES
PUMPS
9.1
-
MECHANICAL
F
AU
L
TS
As
the
system
is
quite
robust
there
are
no
apparent
mechanical
problems.
Occasionally
there
might
be
a
loss
of
liquid
from
the
nipple
because
the
tube
nut
has
loosened,
or
more
simply
the
discharge
tubing-has
broken.
Ve
ry
rarely
there
may
be
losses
caused
by
the
breakage
of
the
membrane,
or
by
the
membrane
seals
in
which
case
they
have
to
be
replaced
by
disassembling
the
four
screws
of
the
pump
head
fig.
10),
when
re-mounting
the
pump
head
ensure
that
the
screws
are
replaced
properly,
along
with
“O”
ring.
After
repair,
the
metering
pump
will
need
to
be
cleaned
of
additive
residues
which
can
damage
the
pump
cas-
ing.
z
1
z
THE
METERING
PUMP
GIVES
PULSES
BUT
THE
ADDITIVE
IS
NOT
INJECTED
a.
Dismount
the
suction
and
discharge
valves,
clean
them
and
replace,
see
position
(fig.
10).
Should
the
valves
be
swollen,
check
valves
material
against
our
chemical
resistance
compatibility
char
t
and
fit
cor
rect
valves.
Standard
valves
are
Viton.
Upon
request
ball
check
valve,
can
be
supplied.
b.
Check
clogging
of
the
filter.
A
TTENTION:
When
removing
the
metering
pump
from
the
plant,
be
carefu
l
as
there
might
be
some
residual
additive
in
the
discharge
hose.
9.2
-
ELECTRICAL
F
AU
L
TS
z
1
z
ALL
LEDS
OFF
,
THE
PUMP
DOES
NOT
PULSE
Check
power
supply
(socket,
plug,
power
switch
ON
),
if
the
pump
doesn’t
work
contact
manufacturer
Customer
Ser
vice,
Dealer
or
Distributor.
z
2
z
GREEN
LED
(POWER)
ON,
RED
LED
(PULSE)
OFF
,
THE
PUMP
DOES
NOT
PULSE
Check
that
the
pump
is
not
in
Alarm
(yellow
LED
flashing,
on
display
LEVEL
has
appeared),
verify
the
calibration's
parameters.
If
the
pump
doesn't
work
contact
Manufacturer
Customer
Service,
Delear
or
Distributor.
z
3
z
PUMP
PULSES
ARE
NOT
CONST
ANT
Check
that
supply
voltage
is
within
+/-
10%
of
rated
voltage.
z
4
z
THE
DOSING
PUMP
GIVES
ONL
Y
ONE
PULSE
Disconnect
the
equipment
and
contact
manufacturer
Customer
Ser
vice,
Dealer
or
Distributor.
DosingPump.ir