ETC Installation Guide
ColorSource PAR v1.5
ColorSource PAR v1.5 Page 10 of 12 ETC
Error codes
There are three error codes that may be shown on the user interface.
: Screen toggles between and to indicate a problem
with the color calibration. The fixture will need to be returned to the
ETC factory; contact your local dealer to set up a repair.
: Screen toggles between and to indicate that the
fixture has gone into over-temperature protection mode to avoid
damaging the fixture. Once the fixture has self-cooled, the error will
automatically clear.
: Screen toggles between and to indicate that the
upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.
RDM values
Parameter Value Description
Manufacturer ID 0x6574 Electronic Theatre Controls
Model ID
0x0201 ETC ColorSource PAR
0x0202 ETC ColorSource PAR Deep Blue
Personality ID
1 5 Channel
2 Direct
3 1 Channel
4RGB