ETC Installation Guide
ColorSource PAR v1.5
ColorSource PAR v1.5 Page 6 of 12 ETC
Setting presets and sequences
There are twelve factory-configured presets followed by five factory-
configured sequences built into the fixture. From the Preset/Sequence menu,
press the Up and Down buttons to scroll through the list. The sequence or
preset plays immediately upon selection. All presets and sequences can be re-
recorded through an RDM device.
Re-recording a preset
1: Using DMX or RDM, set the desired RGB levels.
2: Press the Mode button to access the Preset/Sequence menu.
3: Using the Up and Down buttons, navigate to the preset number that
you want to re-record.
4: Hold the Mode button for 3 seconds to confirm the preset selection.
The user interface will show a 3-second countdown. The preset
number blinks once to confirm that the preset has been recorded.
It is possible to activate a known preset or sequence from a connected fixture
when DMX is not present. If a connected fixture activates a preset or
sequence that is not recognized by the PAR, the PAR will hold its last look.
When DMX is restored, the DMX takes priority.
Note:
When the fixture is in Direct mode (
) or 1-channel
mode (
), you cannot re-record presets.
When you re-record presets with the fixture in RGB
mode (
), the intensity is set to full and the strobe is
turned off.
See Changing the DMX control mode on page 8.