38 - Troubleshooting
Problem Solution
My booth, connected to a
T-Max® Manager, did not
display a delay time but
does indicate:
0:00
a tanning time and the
lamps have come on
a tanning time but the
lamps have not come on
When auto-addressing the
first bed does not register
an address
When using a T-Max® 1A
my booth won’t function
properly
My salon suffers frequent,
short power outages and
clients complain about los-
ing session time
1. Set remote device.
2. See Remote Connections.
1. Set delay time on T-Max® Manager.
2. Set a longer delay time if desired.
Auto start function of T-Max® Manager has
been turned off. Press the START button to
turn on lamps.
When using the auto address feature of the T-
Max® Manager you must wait 10 seconds
from the time you start the auto address func-
tion before addressing the first bed.
Remote Bypass plugs or terminator plugs may
be needed if the T-Max® 1A and the booth are
over 100 feet apart. Install the plugs in the
open remote port in the booth and the T-
Max® 1A.
If you have a T-Max® Manager, changing
parameter 23 from “0” to “1” will allow the
tanning booth to remember how much time
was left when power goes out and resume its
session after power is restored. Consult your
T-Max® Manager manual for information on
setting parameters.
Cause
1. Remote device has
not been set
2. The booth has not
been connected to
the remote system
1. Delay time of T-
Max® Manager has
not been set
2. Delay time has
expired
Auto-start not on
Terminator plugs not
installed