EasyManua.ls Logo

EUCHNER CET-AR Series - Page 28

EUCHNER CET-AR Series
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
28
(Translation of the original operating instructions) 2110788-13-03/20
Monitoring
Output
Safety Inputs
Read Head
Actuator
GNRD
Safety Outputs
Connected load
LED1
X2:2
LED2
X2:3
-B1
UB
X1:2
UCM
X2:4
X2:1
0V(UCM)
RST
X1:8
X1:7
0V(UB)
J
X2:5
X1:5
OUT
X1:3
OA
X1:4
OB
IA
X1:6
IB
X1:1
1
2
-F2
1
2
-F1
13
14
-S1
12
11
14
-S2
24V DC
0 V
24V DC
0 V
CET
Figure 4: Wiring diagram A, CET 1/2-AR with plug connectors 2 x M12
Single-channel control of the guard locking solenoid
0 V
Monitoring
Output
Safety Inputs
Read Head
Actuator
GNRD
Safety Outputs
4/8 F-DI
Digital
Output
PWR
Supply of
the control
4F-DO
LED1
X2:2
LED2
X2:3
-B1
UB
X1:2
UCM
X2:4
X2:1
0V(UCM)
RST
X1:8
X1:7
0V(UB)
J
X2:5
X1:5
OUT
X1:3
OA
X1:4
OB
IA
X1:6
IB
X1:1
-X1
DI4 DI0 DODC24V M
-X1
DO..P DO..M
1
2
-F1
1
2
-F2
24V DC
0 V
24V DC
CET
Figure 5: Wiring diagram A, CET 1/2-AR with plug connectors 2 x M12
Dual-channel control of the guard locking solenoid

Table of Contents

Related product manuals