EasyManuals Logo

EUCHNER CET-AR Series User Manual

EUCHNER CET-AR Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
32
(Translation of the original operating instructions) 2110788-13-03/20
Connected load
GNRD
Monitoring
Output
Safety Inputs
Read Head
Actuator
Door
monitoring
Safety Outputs
Monitoring Outputs
1
2
-F2
1
2
-F1
13
14
-S1
LED1
15
LED2
16
-B1
UB
6
UCM
1
18
0V(UCM)
RST
7
J
13
19
0V(UB)
10
OUT
4
OA
5
OB
IA
2
IB
3
NC
9
NC
11
NC
14
NC
17
8
OUTD
12
FE
12
11
14
-S2
24V DC
0 V
24V DC
0 V
CET
Figure 12: Wiring diagram E, CET 3/4-AR with plug connector M23, versions with and without teach-in input
Single-channel control of the guard locking solenoid
4/8 F-DI
Digital
Output
PWR
Supply of
the control
4F-DO
0 V
GNRD
Monitoring
Output
Safety Inputs
Read Head
Actuator
Door
monitoring
Safety Outputs
Monitoring Outputs
-X1
DI4 DI0 DODC24V M
-X1
DO..P DO..M
1
2
-F1
1
2
-F2
LED1
15
LED2
16
-B1
UB
6
UCM
1
18
0V(UCM)
RST
7
J
13
19
0V(UB)
10
OUT
4
OA
5
OB
IA
2
IB
3
NC
9
NC
11
NC
14
NC
17
8
OUTD
12
FE
24V DC
0 V
24V DC
CET
Figure 13: Wiring diagram E, CET 3/4-AR with plug connector M23, versions with and without teach-in input
Dual-channel control of the guard locking solenoid