EVCO S.p.A. EVJ800 | Installer manual ver. 2.0 | Code 144J800E204
page 24 of 50
The display will show the count-down for the remaining time. At the end of the cycle the buzzer sounds for 1 second
and the device returns to the Home page.
6.10 Heating the needle probe
Heating of the needle probe is a cycle that is only available if the load managed by the K5 output is the needle probe
heater (u2 = 2).
The heating must be carried out with the door open but if the door is closed once the cycle has already started, it does
not affect its functioning.
Access the SPECIAL CYCLES menu from the key and select NEEDLE HEATING: at this point the start screen
will appear. The next time that is pressed the cycle will start, but it can be interrupted at any time by pressing
and holding the key down for 2 seconds.
The needle probe heating output is activated at maximum for the time set by parameter u8 or until the temperature
indicated by the needle probe has reached that set by parameter u7.
At the end of the heating, the buzzer sounds for one second and the device returns to the Home page.