FACT — Factory
The Factory tools contain a group of settings that require factory assistance when setting. These settings are generally never adjusted and involve things
that can really mess up your day, and your oven, if you don’t know what you’re doing. Therefore, these settings are not available without consultation
with Evenheat technicians.
TCOS — Thermocouple Offset — In the unlikely event that a thermocouple is reading temperature incorrectly it’s possible to offset the
displayed temperature to match the actual chamber temperature. It’s a cool feature from the technical standpoint, yet is rarely used in the
practical sense. Our technical staff will most likely dissuade you from going down this road before attempting other possible solutions.
MAX — Maximum Programmable Temperature — We limit the maximum programmable temperature to 2200°F on heat treat ovens.
TYPE —Thermocouple Type Selection - The Rampmaster is capable of being fitted with either a Type K or Type S thermocouple. Type K is
factory supplied on all heat treat ovens.
OUT4 — Output 4 — Has No Use in Heat Treating.
RALL — Has No Use in Heat Treating.