44
Using Your Evinrude E-TEC Outboard
Start Mode
If any of the LEDs does NOT light during start-
ing, it may indicate an engine problem. Refer
to EMM Diagnostics Label.
LED 1, 2, or 3 OFF, seek assistance to return
to port. See your service technician.
LED 3 flashing indicates a hazardous fuel
condition may exist. Seek assistance to return
to port. See your service technician.
LED 4 OFF indicates the stop circuit is activat-
ed, make sure the engine cut–off switch teth-
er cord is attached.
LED 4 flashing indicates engine shut down:
• EMM temp. OVER range, refer to Trouble-
shooting on page 63.
• Engine temp. OVER range, refer to Trou-
bleshooting on page 63.
• Excessive No Oil condition. Seek assis-
tance to return to port.
EMM Diagnostics Label 008539
WARNING
If the outboard shuts OFF and the
“LED 3” indicator is flashing, the out-
board cannot be restarted. A hazardous
fuel condition may exist.
Seek assistance to return to port. Seek
service from an authorized Evinrude
dealer, repair shop, or person of your
own choosing for maintenance, repair, or
replacement.
EMM DIAGNOSTICS
3011761
STARTING MODE
RUNNING MODE
- CHARGING
OK
- CRANK POSITION
OK
- SENSORS
OK
- LANYARD / STOP
OK
- CHARGING
FAULT
- INJECTOR / IGNITION
FAULT
- SENSOR
FAULT
- NO OIL / OVERHEAT