EvoHeat Evo270 Hot Water Heat Pump Manual
7.1 Troubleshooting Guide
Bottom water temp. failure
The water bottom temp. sensor is open or
short circuit.
Check or change the water
bottom temp. sensor
Top tank water temp. failure
The water top tank temp. sensor is open or
short circuit
Check or change the water
top tank temp. sensor
The ambient temp. sensor is open or short
circuit
ambient temp. sensor
The pipe temp. sensor is open or short
circuit
temp. sensor
failure
The evaporator temp. sensor is open or
short circuit
evaporator temp. sensor
Anti-freeze temp. failure
The anti-freeze temp. sensor is open or
short circuit
Check or change the anti-
freeze temp. sensor
The exhaust pressure is high, high pressure
switch action
Check high pressure switch
and cooling return circuit
The suction pressure is low, low pressure
switch action
Check low pressure switch
and cooling return circuit
No water or litter water in water system
volume pump failure
protection
Water flow volume not enough, water
system pressure difference is small
volume system is jammed
Water flow volume not enough, water
system pressure difference is small
volume system is jammed
Anti-freeze protect level 1
Ambient temperature is too low
Anti-freeze protect level 2
Ambient temperature is too low