page 32 of 49
The charger comes with a preconfigured backend server address and UID, which can be
found and, if necessary, changed, in the “Backend Configuration” tab:
In the "Date & Charge Times Configuration" tab, the device local time can be adjusted, the
default charging profile times can be set for offline use, and the randomized delay time value
can be configured. Note that the charger will automatically set its date and time when online:
Important note: the charger is compliant with the UK Electric Vehicles (Smart Charge Points)
Regulations 2021 and includes the charging times and randomized delayed start (RDS)
specifications of Pt. 2/art 10/p-ph 4(a)(b) and Pt. 2/art 11/p-ph 2(a). In its default configuration,
the charger will comply to those time profiles and will not permit charging as specified by the
periods. Likewise, in offline mode, it will apply RDS. These features can be modified or disabled
in the "Date and Charge Times Configuration" window.
Current server
address and UID
UID and server web
address may be
changed in accordance
to the OCPP provider
Note: changing the UID does NOT change
the device serial #, as that is hardwired