3.2. Power Supply
Redundant Power Supply
The server is fitted with two auto switching and hot-swappable power supplies.
The secondary hot-swappable power supply should be connected to the mains to allow
automatic power switching to this second power supply should the first one fail.
Grounding
Warning
The protective earth must be connected to the ground before powering up the
unit.
Ensure the disk recorder unit is properly grounded at all times to avoid electrical
shock hazard.
Electrical Specifications
Rated voltage: 115 to 240 VAC (single phase)
Rated frequency: 47-63 Hz
Input connector: CEE 22/IEC 320 3-pin male receptacle
Connection to supply: Pluggable equipment Type A (EN60950 §1.2.5): Equipment which
is intended for connection to the building power supply wiring via a non-industrial plug and
socket-outlet or a non-industrial appliance coupler or both. Correct mains polarity must
always be observed. Do not use reversible power plugs with this equipment.
Class of equipment: Class 1 equipment (EN60950 § 1.2.5): electric shock protection by
basic insulation and protective earth.
3.3. Environmental Conditions
Operating
• Temperature: 10°C to + 50°C (50°F to 122°F) ambient with free air flow
• Relative humidity: 0% to 90% (non-condensing)
• Cooling requirements: Forced air cooling air flow from front to back
• Handling/movement: Designed for fixed use when in operation
8 3. Hardware Specifications