Page #13 background imageLoading...
Page #13 background image
EXCELL PRECISION CO., LTD
02005159 ZSME300000350
12
1-8 Error Messages
The EEPROM is not working correctly.
The EEPROM is not set yet, or the circuit on PCB is broken.
Zero is higher than the zero range when switching the indicator on.
Zero is lower than the zero range when switching the indicator on.
A/D value is unstable.
The weight of the object is over 9 divisions of the maximum capacity .
The weight of the object is under -1/6 maximum capacity.
ADIC value is over the maximum range.
The scale is not in level status.
(Only available with level detector equipped)
1-9 Weight Units
kg
1 g = 0.001 kg
g
1 g = 1 g
lb
1 g = 0.002204623 lb
lb/oz
1 g = 0.03527396 oz
oz
1 g = 0.03527396 oz
GN
1 g = 15.432358 GN
dwt
1 g = 0.6430149 dwt
ct
1 g = 5 ct
hk.tael
1 g = 0.02645546 Hk.catty
viss
1kg = 0.612245 viss

Questions and Answers: