Troubleshooting
Troubleshooting
Important:Itisessentialthatalloperatorsafetymechanismsbeconnectedandinproperoperating
conditionpriortomoweruse.
Whenaproblemoccurs,donotoverlookthesimplecauses.Forexample:startingproblemscouldbecaused
byanemptyfueltank.
Thefollowingtablelistssomeofthecommoncausesoftrouble.Donotattempttoserviceorreplacemajor
itemsoranyitemsthatcallforspecialtimingofadjustmentprocedures(suchasvalves,governor,etc.).Have
thisworkdonebyyourEngineServiceDealer.
Note:WhendisconnectingelectricalconnectorsDONOTpullonthewirestoseparatetheconnectors.
ProblemPossibleCauseCorrectiveAction
1.PTOisengaged.
1.DisengagethePTO.
2.Parkingbrakeisnotengaged.2.Settheparkingbrake.
3.Driveleversarenotinneutrallock
position.
3.Ensurethedriveleversareintheneutral
lockposition.
4.Batterydoesnothaveafullcharge.
4.
Chargethebattery.SeeCheckBattery
ChargeandRecommendedJump
StartingProceduresectionsin
Maintenance.
5.Electricalconnectionsarecorroded,loose
orfaulty.
5.Checktheelectricalconnectionsfor
goodcontact.Cleanconnectorterminals
thoroughlywithelectricalcontactcleaner,
applydielectricgreaseandreconnect.
6.Fuseisblown.6.Replacetheblownfuse.
7.
Relayorswitchisdefective.
7.
ContactanAuthorizedServiceDealer.
Starterdoesnotcrank
8.Faultymodule.8.Replacemodule.
1.Fueltankisempty.1.Fillthefueltank.
2.Fuelshutoffvalveisclosed.
2.Openthefuelshutoffvalve.
3.Oillevelinthecrankcaseislow.
3.Addoiltothecrankcase.
4.Thethrottleandchokearenotinthe
correctposition.
4.Besurethethrottlecontrolismidway
betweenthe“SLOW”and“FAST”
positions,andthechokeisinthe“ON”
positionforacoldengineorthe“OFF”
positionforawarmengine.
5.Dirtinfuellter.5.Replacethefuellter.
6.Dirt,water,orstalefuelisinthefuel
system.
6.ContactanAuthorizedServiceDealer.
7.
Aircleanerisdirty.
7.Cleanorreplacetheaircleanerelement.
8.Seatswitchisnotfunctioningproperly.
8.Checktheseatswitchindicator.Replace
seatifneeded.
9.
Electricalconnectionsarecorroded,loose
orfaulty.
9.Checktheelectricalconnectionsfor
goodcontact.Cleanconnectorterminals
thoroughlywithelectricalcontactcleaner,
applydielectricgreaseandreconnect.
10.Relayorswitchisdefective.10.ContactanAuthorizedServiceDealer.
11.Faultysparkplug.
11.
Clean,adjustorreplacesparkplug.
12.Sparkplugwireisnotconnected.
12.
Checkthesparkplugwireconnection.
13.
Faultymodule.
13.
Replacemodule.
Enginewillnotstart,startshard,orfailsto
keeprunning
14.MILilluminatesandblinks14.ContactanAuthorizedServiceDealer
77

Table of Contents

Other manuals for Exmark LAZER Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Exmark LAZER Z and is the answer not in the manual?

Exmark LAZER Z Specifications

General IconGeneral
Engine BrandKawasaki
TransmissionHydrostatic
Deck ConstructionFabricated or welded steel
CategoryCommercial
TypeCommercial
Speed10 mph
Turning RadiusZero-turn
Fuel Capacity10-15 gallons
Weight1, 465 lbs

Related product manuals