EasyManua.ls Logo

Exmark VANTAGE - Periodic Maintenance Checks

Exmark VANTAGE
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
MaintenanceService
Interval
MaintenanceProcedure
Every500hours
Replacethesecondaryaircleanerelement.(Mayneedmoreoftenundersevereconditions.
SeetheEnginemanualforadditionalinformation.)
Changethehydrauliclteranduid(Every250hours/yearlyifusingMobil115W50)
Checkthewheelhubtorquespecication.
Checkthewheellugnuts.
Yearly
Greasethefrontcasterpivots.
Greasethedeckbeltidlerpivot.
Lubricatethecasterwheelhubs.
PeriodicMaintenance
CheckEngineOilLevel
ServiceInterval:Beforeeachuseordaily
1.Stopengineandwaitforallmovingpartstostop.
Makesureunitisonalevelsurface.
2.Checkwithenginecold.
3.Cleanareaarounddipstick.Removedipstickand
wipeoiloff.Reinsertthedipstickandpushitall
thewaydownintothetube.DoNotscrewinto
place.Removethedipstickandreadtheoillevel.
4.Iftheoillevelislow,wipeofftheareaaroundthe
oilllcap,removecapandaddoiltothe“FULL
markonthedipstick.Exmark4-CyclePremium
EngineOilisrecommended;refertotheEngine
Owner’smanualforanacceptablealternative.Do
Notoverll.
Important:DoNotoperatetheenginewiththe
oillevelbelowthe“LOW”(orADD”)markon
thedipstick,oroverthe“FULL”mark.
CheckBatteryCharge
ServiceInterval:Asrequired
WARNING
CALIFORNIA
Proposition65Warning
Batteryposts,terminals,andrelated
accessoriescontainleadandlead
compounds,chemicalsknowntotheStateof
Californiatocausecancerandreproductive
harm.Washhandsafterhandling.
Allowingbatteriestostandforanextendedperiodof
timewithoutrechargingthemwillresultinreduced
performanceandservicelife.Topreserveoptimum
batteryperformanceandlife,rechargebatteriesin
storagewhentheopencircuitvoltagedropsto12.4
volts.
Note:Topreventdamageduetofreezing,battery
shouldbefullychargedbeforeputtingawayfor
winterstorage.
Checkthevoltageofthebatterywithadigital
voltmeterorwiththemessagedisplay.Iftheignition
keyisturnedtothe“on”positionforafewseconds,
thebatteryvoltagewillbedisplayedintheareawhere
thehoursarenormallydisplayed.Locatethevoltage
readingofthebatteryinthetableandchargethe
batteryfortherecommendedtimeintervaltobring
thechargeuptoafullchargeof12.6voltsorgreater.
Important:Makesurethenegativebatterycable
isdisconnectedandthebatterychargerusedfor
chargingthebatteryshouldhaveanoutputof
16voltsand7ampsorlesstoavoiddamaging
thebattery(seechartforrecommendedcharger
settings).ThisisespeciallyimportantonKohler
EFI(ElectronicFuelInjection)units.Failureto
dosomaydamagetheECU(ElectronicControl
Unit).
Voltage
Reading
Percent
Charge
Maximum
Charger
Settings
Charging
Interval
12.6or
greater
100%
16volts/7
amps
No
Charging
Required
12.412.675–100%
16volts/7
amps
30Minutes
12.212.450–75%
16volts/7
amps
1Hour