ATTACHMENT 2 - TROUBLESHOOTING
Wave Flamer doesn't ignite.
Clean electrodes with toothbrush
Defective ignition electrode
Check electrode for any obvious damages. (If damaged – Contact manufacturer)
Damaged ignition electrode cable.
Check isolation of ignition electrode cables. ( If damaged – Contact manufacturer)
Other (eg. internal damages to the system)
Fluid unsuitable for temperatures
Consult MSDS of the fluid and check temperature range.
Wrongly mounted ignition electrode
Adjust according to attachment 3.
Dismount nozzle and clean with clear fluid and pressurized air.
Open side panel, build pressure and find weak spot. Contact manufacturer.
Wave Flamer head is leaking.
Contact manufacturer. Shipment of spare parts possible.
Change rubber sealing ring.
Check power supply (max. power per Wave Flamer is 350W).
Wave Flamer doesn't pump.
Contact manufacturer (Guide to cleaning the valve possible).
Wave Flamer pumps continuously.
Wave Flamer head doesn't move.
Wave Flamer can't be controlled.
Check usage mode and system settings. Consult manual.
Defektive DMX controller or DMX cable
Display shows an error-code.
Wave Flamer can't be switched on.
Problem with the power supply
Check supply line (eg damage to power cable or the fuze).