29
MONROC
Adjusting group temperature
Factory defaults. Reset of parameters
Alarms of the thermostat
MULTIBOILER MODELS TEMPERATURE CONTROL
To adjust the temperature for each group, proceed as follows:
With the main switch on and the thermostat in normal mode:
Press briey the button “ ”. The thermostat will show the message
“PrG” on the display. (See g. M)
Immediately, press briey the button “ ”, the display will show the
setting temperature “set point”. (See g. N)
Increase ( ) or decrease ( ) the value of this temperature
through the buttons.
Have in mind that after 3 seconds since the last actuation on the buttons,
the thermostat will automatically come back to the normal mode.
If, due to any reason, the working parameters of the thermostat became
miscongured or just an abnormal performance of the brewing group
temperature was observed; don’t have any doubt, it will be very likely solved
by resetting the parameters of the thermostat, coming it back to factory
defaults. To perform a factory reset:
With the main switch off, keep pressed the button “ ” and then
switch the machine on.
When the thermostat display shows “PrS”, release the button. (See g. O)
To came back to normal mode, just switch off and again on the machine
from the main switch.
In case of temperature probe disconnected, the display will show the
error message “A1”. (See g. P)
In case of temperature probe short-circuited, the display will show the
error message “A2”. (See g. Q)
g. M
g. N
g. O
g. P
g. Q