CG206‐en‐GB_v1.06/16
2
Introduction
ThankyouforselectingtheExtechCG206CoatingThicknessTester.TheCG206isaportable
meterdesignedfornon‐invasivecoatingthickness measurementswithautomaticrecognitionof
thesubstratematerialundertest.
Themeterusestwomeasurementmethods:magneticinduction(forferrousmetalsubstrates)
andeddycurrent(fornon‐ferrousmetal
substrates).
TheCG206metercanconnecttoaPCviaUSBandtransmitrecordeddataforfurtheranalysis and
forgeneratingreportdocumentation.
Properuseandcareofthismeterwillprovidemanyyearsofreliableservice
.
Features
MeasuredCoatings:Non‐magneticcoatings(e.g.paint,zinc)onsteel;InsulatedCoatings(e.g.
paint,anodizedcoatings)onnon‐ferrousmetals
Intuitivemenu‐basedprogramming
Memorystorageofupto1500readingsin30groups(50readingspergroup)
Deletesinglereadingsorallgroupseasily
Auto
PowerOFFwithdisablefeature
DatatransfertoPCviaUSB
UserZeroCalibrationability
Applications
Corrosionprotection
PaintShopsandElectroplaters
Chemical,Automobile,Shipbuilding,andAircraftindustries
Laboratory,Workshop,andFielduse
ProbeDescription
TheCG206probeisspringmountedinthesensorsleeve.Thisensuressafeandstablepositioning
oftheprobeandensuresconstantcontactpressure.
AV‐grooveinthesleeveoftheprobefacilitatesreliablereadingsonsmallcylindricalparts.The
hemisphericaltipoftheprobeismadeofhardand
durablematerial.
Measuringmetalliccoatings
Thismetercanmeasurenon‐magneticmetalcoatings(Zinc)ona magnetic(ferrous)substance
base,andnon‐metalcoatingsonametalbase(ferrousornon‐ferrous).