5
MIN/MAXDataRecording
Whenselected,theDataRecordingfunctionrecordstheMin/Maxreadings.Tostartadata
recordingsession:
1. PresstheRECbuttononce.TheRECindicatorwillappearonthedisplay.PresstheREC
buttonagainandRECMAXwilldisplayonthescreenalongwiththemaximumvalue.
2. Pressthe
RECbuttonagainandthedisplaywillshowRECMINandtheminimumvaluewill
bedisplayed.
3. ToreleasetheheldMAXorMINreading,presstheHOLDbuttonwhileeithertheRECMAX
orRECMINiconsarevisible;nowonlytheRECiconwillbevisible.The
meterisnow
continuingtomonitorthehighest(MAX)andlowest(MIN)readingsbutisdisplayingreal
timemeasurements.ToviewtheMAXandMINvaluesagainusetheRECbuttonas
describedearlier.
4. ToexittheRecordmode,pressandholdtheRECbuttonforatleast2seconds.Thedisplay
willreturntothenormaloperatingmode.
SettingsMode
BeforeaccessingtheSettingsmodeensurethatthemeterisnotintheHOLDorMIN/MAX
Recordingmodes.TousetheSettingsmode:
1. PressandholdtheSETTINGbuttonforatleast5seconds(untilabeepisheard)
2. UsetheSETTINGbuttontoscrollthroughtheSettingsoptionsTheoptionsare:
HIGH Altitudecompensationadjustment
SALt %Saltadjustment
°C/°F Temperatureunitselection
OFF Autopoweroffmanagement
3. RefertothefollowingsectionsfordetailedinstructionsonprogrammingtheSetting
modeparameters
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extech Instruments DO210 and is the answer not in the manual?

Extech Instruments DO210 Specifications

General IconGeneral
BrandExtech Instruments
ModelDO210
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals