Hardware Mounting and Installation
AP-7562 Installation Guide 28
7 Rotate the Access Point bracket upward, and align the top holes on the sides with the
top holes on the angle adapter bracket. Insert two M6 hex flange screws into the top
holes on the angle adapter bracket.
8 Use a torque wrench or a ratchet and a 10mm socket, or an adjustable wrench, to finish
attaching the Access Point bracket to the angle adapter bracket with the M6 hex flange
screws in the open slot connections and the top holes on the angle adapter bracket. Do
not tighten the screws until all rotation and tilt adjustments are complete.
9 To adjust the position of the Access Point, rotate the Access Point bracket (plus or minus
15 de
grees) and tilt the angle adapter bracket (up to 45 degrees).
10 Tighten all hex flange screws to 60 inch pounds (lbf-in).
For mounting with band clamps: