Hardware Mounting and Installation
AP-7562 Installation Guide 29
1 Attach the pole mount bracket at the desired mounting location using band clamps.
2 With the angle adapter bracket positioned so the open connector slots are on the
bottom, attach the angle adapter bracket to the pole mount bracket using two 1/2 inch
bolts and nuts. Tighten the nuts to 300 inch pounds (lbf-in).
3 Position the Access Point bracket so the bottom of the bracket with the straight (not
be
vel cut) sides is oriented toward the bottom side of the AP with the gore vent. Attach
(but don’t tighten) the bracket to the AP-7562 with the four M6 hex flange screws using
a torque wrench, a ratchet and a 10mm socket or an adjustable wrench.
4 Insert two M6 hex flange screws into the bottom holes on the sides of the Access Point
br
acket.
5 Position the Access Point so the gore vent is f
acing down. Insert the two M6 hex flange
screws in the bottom holes on the sides of the Access Point bracket into the open slot
connections on the bottom of the angle adapter bracket.