20 CrossPoint / MAV Matrix Switchers • Remote Control
Command SIS command
(host to switcher)
Response
(switcher to host)
Aditional information
IP setup
Set IP address
EX1#
CI
}
Ipi
X1#]
Read IP address
E
CI
} X1#]
Set subnet mask
EX1#
CS
}
Ips
X1#]
Read subnet mask
E
CS
} X1#]
Set gateway IP address
EX1#
CG
}
Ipg
X1#]
Read gateway IP address
E
CG
} X1#]
Set DHCP on or off
EX1$
DH
}
Idh
X1$]
Read DHCP on/off status
E
DH
} X1$]
Set verbose mode
EX1%
CV
}
Vrb
X1%]
Read verbose mode
E
CV
} X1%]
Congure current port timeout
E
0*
X1^
TC
}
Pti0*
X1^]
Read current port timeout
E
0TC
} X1^]
Congure global IP port timeout
E
1*
X1^
TC
}
Pti1*
X1^]
Read global IP port timeout
E
1TC
} X1^]
KEY: X1# = IP address ###.###.###.###
X1$ = DHCP
0
=off,
1
= on
X1% = Verbose mode
0
= clear/none (default for Telnet connection)
1
= verbose mode (default for RS-232/RS-422 connection)
2
= tagged responses for queries
3
= verbose mode and tagged for queries
X1^ = Port timeout interval
1
(= 10 seconds) -
65000
(default is
30
= 300 seconds = 5 minutes)

Other manuals for Extron electronics CrossPoint 450 Plus Series