6
ENGLISH
ENGLISH
These instructions apply to the following models:
Appliances 596MPS - 610MPS
1. DESCRIPTION
The 596MPS electronic appliance is suitable for controlling up-
and-over automatic systems with single or double hydraulic
operator.
The 610MPS electronic appliance is suitable for controlling barriers
with a hydraulic operator.
1.1. TECHNICAL SPECIFICATIONS
TABLE 1 OPERATING PARAMETERS OF 596MPS & 610MPS
(dip-switch selectable)
596MPS 610MPS
Logic automatic (A) / semi-automatic (E)
Pause time (sec.) 30/60 0/2/5/10/15/30/60
Work time (sec.) 25/30/35/40 4/5/7/9
Failsafe enabled/disabled
TABLE 2 HARDWARE CHARACTERISTICS OF 596MPS & 610MPS
Power supply 230V~ (+6 -10 %) 50Hz
Max absorbed power 10 W
Motors max. load 800 W
Power supply for accessories 24Vdc
Accessories max. load 250 mA
Ambient temperature - 20°C V + 55°C
Fuses motor/accessories
Rapid connectors for decoding-RP receiver cards
push-button for outside opening
Terminal boards removable
Open
Terminal board inputs Stop
Closure safety devices
Limit-switch
Terminal board outputs motor
capacitor
24 Vdc accessories power supply
courtesy light (596MPS)
flashlight (610MPS)
Courtesy timing 90 sec. (596MPS)
1.2. LAY-OUT OF 569MPS & 610MPS CARD
2. ELECTRICAL CONNECTIONS
Ü
Before attempting any work on the card (connections,
programming, maintenance), always turn off power.
Observe points 10, 11, 12, 13 and14 of the GENERAL SAFETY RULES.
Always separate 230V~ power cables from control and safety
cables (push-button receiver, photocells, etc.).
To prevent any electric noise whatever, use separate sheaths.
2.1. 596MPS CONNECTION LAY-OUT
(photocell with failsafe enabled)
2.2. 610MPS CONNECTION LAY-OUT
(photocell with failsafe enabled)
876543219
16151413121110
1817 19
J2
F2
J4
DS1
123456
ON
TF1
F1
J1
J3
IC1
J9
RL1
RL3
RL2
F1
J4
J9
J3
DS1
J1 J2
F2
J1
5
4
3
2
1
2
1
M1 M2
OPEN
FCC
FSW
STOP
+24V
FAIL-SAFE
FCA
J2
J9
SERVICE LIGHT
230V~ 40W max
FAACLAMP
MINILAMP
C1
C2
TXRX
596MPS
Altre sicurezze
Other safeties
Autres sécurités
Andere Sicherheiten
Otros disp. seg.
230V~
(+6% -10%)
50Hz
8
7
654
3
219
16
15
14
13121110
1817 19
J1
5
4
3
2
1
2
1
230V~
(+6% -10%)
50Hz
M1 M2
OPEN
FCC
FSW
STOP
+24V
FAIL-SAFE
FCA
J2
J9
FAACLAMP
MINILAMP
C1
C2
TXRX
610MPS
Altre sicurezze
Other safeties
Autres sécurités
Andere Sicherheiten
Otros disp. seg.
8
7
654
3
219
16
15
14
13121110
1817 19
TABLE 3COMPONENTS OF 596MPS & 510MPS CARD
F1 Fuse F1 5x20 5A/250V (motor/transformer primary winding)
F2 Fuse F2 5x20 0.5A/250V delayed (accessories power supply)
DS1 Programming microswitches
J1 Low voltage input/accessories terminal board
J2 Output terminal board for motor/capacitor/lamp
J3 Rapid connector for decoding/RP receiver cards
J4 Rapid connector for Open push-button
J9 230V power supply input terminal board
Fig. 2
Fig. 3
Fig. 1
596MPS & 610MPS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC 596MPS and is the answer not in the manual?

FAAC 596MPS Specifications

General IconGeneral
BrandFAAC
Model596MPS
CategoryController
LanguageEnglish

Related product manuals