950N 8 732708 - Rev. C
ENGLISH
ITALIANO
The 950 N automated system for leaf doors is an enbloc
consisting of an electromechanical device that allows door
opening by means of a transmission arm. The door closes
itself using a spring system.
The operator can be installed either on the architrave or
directly on the door structure.
The protective housing contains the electronic control unit
for system programming and operation control. The 950 N
operator is a reversible operator. Therefore, in the event of
power drop, the door can be opened manually.
Automated system
power supply
230 V~* or 115 V~*
(+6% -10%)
(* Depending on the model)
Absorbed power 100 W
Absorbed current 0,5 A
Electric motor 24 V= with encoder
Dimensions 530 x 105 x 160
L x H x D
Weight 10 Kg
Operating ambient
temperature
- 20° C..........+55°C
Protection
class
IP 23 (indoor use)
Maximum leaf
dimensions and
weight
Section 3
Use frequency continuous
ROT Continuous use at 55°C
Operation with
no power
manual push or pull opening
depending on the arm
Type of transmis-
sion arms
Articulated
Sliding L=330 mm
Sliding L=430 mm
Anti-crushing
device
With reverse in case of obstacle
(standard supply)
Maximum
opening angle
Section 3.3
950 N
2 DESCRIPTION AND TECHNICAL SPECIFICA-
TIONS
Opening
time
adjustable
from 4 to 10 seconds
Closing
time
adjustable
from 4 to 10 seconds
Accessories power
supply+ Electric
lock power supply
24 V =
1000mA max
Operating modes
(by selector switch)
Open - Automatic -
Manual or Night
Pause time adjustable
from 0 to 30 seconds
Modes adjustable
and 6
Terminal board
outputs
Board fault signal
Electric lock activation
Accessories power supply
Door status signal
Exchange relay controlled
from card reader
2-leaf connection signal
Signal for interlock between
two doors
Terminal board
inputs
Open commands
Emergency command
Key command
Card reader command
Fire-prevention command
STOP safety
Safety during closing
Rapid connectors
KP controller/SDK light
(optional)
Radio rp, minidec, decoder
board connector
Mode selector switch
connector
Mode selection Mode selector switch
KP controller
SDK light
1 PRELIMINARY CHECKS
For correct operation of the automated system, the existing door structure must feature the following:
1. Length and weight corresponding to the description contained in section 3.1
2. Max. post depth corresponding to the description contained in section 3.2
3. Sturdy and rigid leaf structure.
4. Existing hinges in good condition.
5. Smooth and even movement of the leaf, without irregular friction during the entire stroke.
6. Door “neutral” position during the entire stroke. Should the door tend to close or open, check the alignment of the hinges.
7. Presence of mechanical limit switches.