950N 18 732708 - Rev. F
950 I/0
F1= 4A
ENGLISH
7 PROGRAMMING AND DESCRIPTION OF THE 950 I/O BOARD
950 I/O BOARD LEDs
LED ON OFF NOTE
LD1 Accessories power present No accessories power
LD2 Card reader active Card reader not active Signals the status of
input 17
LD3 Internal opening command active Internal opening sensor
not active
Signals the status of
input 10
LD4 External opening command active External opening sensor
not active
Signals the status of
input 11
LD5 Emergency command not active Emergency command active Signals the status of
input 12
LD6 The opening STOP safety sensor is
not engaged
STOP safety active Signals the status of
input 13
LD7 The closing safety sensor is not
engaged
Closing phase safety
occupied
Signals the status of
input 14
LD8 Key command active Key command not active Signals the status of
input 15
LD9 Fire-prevention command active Fire-prevention command not
active
Signals the status of
input 16
BOLD PRINT INDICATES THE DEFAULT CONDITION WITH DOOR IN REST POSITION
SW1= SET-UP START BUTTON
950 I/O DS1 SETTING
FUNCTION OFF ON
1
Pause time following ope-
ning using the “push and
go” function.
2
seconds
Value set in automatic mode (using TR3 or
KP controller trimmers)
2
Opening delay for door
with electric lock
200 milliseconds
(the electric lock re-
mains active up to a 70°
opening)
500 milliseconds
(the electric lock remains active for over a 70°
opening)
Inversion stroke starting from a closed position.
J7 = COUPLING FOR RADIO RECEI-
VER (RP, MINIDEC, DECODER)
J10 = 950 MPS POWER CONNECTOR
J11 = RAPID CONNECTOR FOR STATUS
SIGNALS TO THE 950 MPS BOARD
Fig.6
J9 = MOTOR POWER INTERRUP-
TION TERMINAL