B614 40 732998 - Rev.A
Translation of the original instructions
ENGLISH
Advanced function Default
P1
OUT OUTPUT 1 POLARITY
Y NC output
no NO output
If output
o1 = 01 (Fail-safe) configure P1 = no.
no
o2
see o1
P2
see P1
o3
see o1
P3
see P1
o4
see o1
P4
see P1
to
OUT OUTPUT 1 TIMING
(only displayed if one of the outputs is configu-
red as courtesy light)
This defines the timing of the output from 1 to 59
minutes in 1 minute steps.
02
bF
BATTERY OPERATION
01 continues to function until completely dead
02 the barrier opens when the mains power is
interrupted
03 the barrier closes when the mains power is
interrupted
01
oS
INTEGRATED flashing light OPERATING MODE
01 light column (steady green with barrier in
pause mode/open, red flashing during movement,
red steady with barrier closed)
02 flashing light (flashing red during move-
ment, off in all other states)
01
bL
BEAM LIGHT OPERATIONAL MODE
01 lights on with barrier closed, off with barrier
in pause mode/open, flashing during the move-
ment
02 lights off with barrier in pause mode/open,
flashing in all other states
01
AS
MAINTENANCE REQUEST - CYCLE COUNTER (linked
to the next two functions)
This can be useful to set scheduled maintenance
interventions.
Y Active
no Excluded
no
nc
CYCLE PROGRAMMING IN THOUSANDS
This makes it possible to set a countdown of the
plant operating cycles from 0 to 99 (thousands of
cycles). The function can be used, in combination
with
nC, to verify the use of the system and for
the “Request for assistance”
00…99 (thousands of cycles)
00
Advanced function Default
nC
CYCLE PROGRAMMING IN HUNDREDS OF THOU-
SANDS
This makes it possible to set a countdown of the
plant operating cycles from 0 to 99 (hundreds of
thousands of cycles). The value displayed is updated
a the cycles progress, integrating with the
nc value.
(1
nC decease corresponds to 99 nc decreases).
The function can be used in combination with
nc, to verify plant use and for the "Request for
Assistance".
00
St
AUTOMATION SYSTEM STATUS:
See
St in the Basic programming
Y