EasyManua.ls Logo

FAAC B680H - Programming; BASIC Programming

FAAC B680H
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B680H 11 732719 - Rev.D
Translation of the original instructions
ENGLISH
5. PROGRAMMING
The E680 board features 3 programming levels that make it entirely
configurable and allow it to adapt the logics to any use.
Each of the three levels can be accessed through a specific key
combination.
Changes to the programming parameters become effective
immediately, while nal storage occurs only upon exiting
con guration and returning to the automated system
status display. If the equipment is powered down before
returning to the automated system status display, all
changes made will be lost.
5.1 BASIC programming
To perform BASIC programming:
1. Press and hold button F; the name of the first function is displayed.
2. Release the button; the function value is displayed and can be
modified using the + and - buttons.
3. Press and hold F again; the name of the following function is
displayed, and so on.
The last function St lets you choose whether to save the configuration
made (
Y) or exit without saving (no). Later, the display will resume
showing the automated system status
You can go to St at any time. To exit programming,
simultaneously press F and -.
BASIC PROGRAMMING
Display
Function Default
cF
Barrier configuration
01 Minimum mass
06 Maximum mass
Before automated system start-up, you must
set the correct value, directly correlated to the
length of the beam and the number and type of
accessories installed. To determine said value,
refer to Tables 4 and 5 on page 25
WARNING: Setting a mass default
lower than the one actually installed
could cause irreversible damage to
the bar and barrier structure.
Loading a different configuration will
reset the parameters to the default
values
06
dF
Default
Y indicates that all values set correspond to
the defaults
no indicates that one or more set values are
different from the defaults. Select Y to
restore the default configuration.
Y
Ct
Master / slave configuration
MA Configures the board in master mode
SL Configures the board in slave mode
For details on MASTER / SLAVE con-
figuration, refer to section 9.
MA
bu
BUS accessories menu
For functions associated with this parameter see
paragraph 5.3
no
Display
Function Default
LO
Operating logics
A Automatic
A1 Automatic 1
E Semi-automatic
P Parking
PA Automatic parking
Cn Condo
CA Automatic condo
C Dead-man
CU Custom
E
PA
Pause time
Is effective only if an automatic logic is chosen;
the value can be set from
O to 59 sec. in one
second steps. Next, the display changes to
minutes and tenths of a second (separated by a
decimal point) and time is adjusted in 10-second
steps up to the maximum value of
4.1 minutes.
e.g. if the display shows
2.5, the pause time will
be 2 minutes and 50 seconds.
20
So
Opening speed
Adjusts the barrier opening speed.
00 Minimum speed
10 Maximum speed
WARNING: Setting an excessive speed could
cause irreversible damage to the beam and
barrier structure.
10
Sc
Closing speed
Adjusts the barrier closing speed.
00 Minimum speed
10 Maximum speed
WARNING: Setting an excessive speed could
cause irreversible damage to the bar and
barrier structure.
02
L1
Loop 1
Activating this parameter, any loop that is
connected to the Loop 1 input will serve as an
OPEN function.
Y Loop 1 enabled
no Loop 1 disabled
Note: Should this function be disabled, the de-
tection status of the loop will in any case remain
available on one of the two outputs, if configu-
red (see parameters
o1... o4 in ADVANCED
programming)
no
L2
Loop 2
Activating this parameter, any loop that is
connected to the Loop 2 input will serve as a
SAFETY/CLOSE function.
Y Loop 2 enabled
no Loop 2 disabled
(see note regarding Loop 1)
no
S1
Loop 1 sensitivity
Adjusts the sensitivity of the vehicle detection
loop
00 Minimum sensitivity
10 Maximum sensitivity
05

Table of Contents

Other manuals for FAAC B680H

Related product manuals