B680H 27 732719 - Rev.D
Translation of the original instructions
ENGLISH
Bar length
Installed
accessories
2 m 2,5 m 3 m 3,5 m 4m
4 m (with
coupling
)
4,5 m 5 m
5 m (with
coupling
)
No
accessories
112223333
Lights
11222333
Lights / Skirt
1123333
Lights / Foot /
Skirt
1223333
Lights / Foot
1223333
Foot
1123333
Skirt
1122333
Skirt/Foot
1223333
Articulated
beam
22333
Table 4
Bar length
Installed accessories
5 m
(without
coupling)
5 m 5,5 m 6 m 6,5 m 7 m 7,5 m 8 m
No accessories
44555556
Lights
44555566
Lights / Skirt
4556666
Lights / Foot / Skirt
555566
Lights / Foot
45555666
Foot
45555566
Skirt
4555566
Skirt/Foot
555556
Table 5
13. DEFAULT SELECTION TABLES (cF parameter)
The purpose of the two following tables is to determine, depending on the length of the bar and the number and type of accessories installed,
the correct default value to set in the first Basic programming function.
Table 4 refers to the balance spring for bar lengths equal to or shorter than 5 m and featuring a profile corresponding to the one in Fig. 8 on
page 26, ref.
(“S” profile).
Table 5 refers to the balance spring for bar lengths equal to or longer than 5 m and featuring a profile corresponding to the one in Fig. 8 on
page 26, ref.
(“L” profile).
The key to symbols for identifying the fixing holes based on the number indicated in the tables is shown in Fig. 30.