B680H 14 732719 - Rev.D
Translation of the original instructions
ENGLISH
DL1 LED description (Red)
On At least one of the inputs (safeties, OPEN pulse) is
engaged or active
Off No OPEN input is active and no safety device is
engaged
DL2 LED description (Green)
On
fixed
Normally active (LED on even if there are no devices
connected)
Off BUS-2EASY line short-circuited (flash every 2.5 sec.)
Rapid flas-
hing
An error has been detected in the BUS-2EASY con-
nection; repeat the acquisition procedure. If the error
persists, check that:
the system does not have more than one acces-
sory with the same address (see also instructions
regarding the accessories)
make sure there is no calling error (number of
devices connected is greater or less than that
stored during setup)
6. ADVANCED programming
To access ADVANCED programming, press F and, while holding it,
also press
+:
• when
+ is released, the number of the first available function
will appear
• when F is also released, the value is displayed, and can be
changed using
+ and -
• pressing F again, and holding it, the name of the next parameter
will be displayed; when released, the value can be changed
using
+ and -
once the last function has been reached, pressing F makes it
possible to either save the previously changed parameters or exit
without saving the changes; the display will go back to showing
the status of the inputs.
ADVANCED PROGRAMMING
Display Function
Default
FO
Opening motor power
Adjusts the thrust of the motor during the opening
phase.
00 Minimum power
50 Maximum power
40
FC
Closing motor power
Adjusts the thrust of the motor during the closing
phase.
00 Minimum power
50 Maximum power
40
PF
Pre-flashing
This parameter is used to activate the flashing lamp
for 5 seconds before the selected movement.
no disabled
OC before each movement
CL before each closing movement
OP before each opening movement
PA only at the end of the pause
no
tP
Pre-flashing time
Pre-flashing time expressed in seconds.
00 minimum pre-flashing
10 maximum pre-flashing
00
Display
Function
Default
oc
Sensitivity of obstacle during closing
This determines the sensitivity to an obstacle before
reversing takes place.
01
Minimum sensitivity
50
Maximum sensitivity
30
o1
Output 1
Setting this function makes it possible to modify the
signal type of output 1, allowing high connection
flexibility with external devices.
00 Failsafe
01 TYPE 1 BEAM ILLUMINATION (output
active when beam closed, disabled with bar
open or paused, intermittent when moving).
Use only with output 4!
02 BAR LIGHTING TYPE 2 ( ashing output
during opening, closing and with rod closed
or stopped. inactive with rod open or
paused).
03 Beam CLOSED
04 Beam OPEN or in PAUSE, it goes off during
closing pre- ashing.
05 Beam in OPENING MOVEMENT, including
pre- ashing.
06 Beam in CLOSING MOVEMENT, including
pre- ashing.
07 Beam STATIONARY
08 Beam in EMERGENCY mode
09 LOOP1 engaged
10 LOOP2 engaged
11 OPEN for E680 slave
12 CLOSE for E680 slave
13 Beam RELEASED
14 Not used
15 Not used
16 FCA engaged
17 FCC engaged
18 Interlock
19 WARNING LAMP (on during opening and
pause, ashing when closing, off when the
automated system is closed)
20 Battery operation
04
P1
Output 1 Polarity
Allows setting of the output polarity:
Y output NC
no output NO
NOTE: if the output setting is
00 (Failsafe), keep
the value set to
no
no
o2
Output 2
Output 2 signal type, see “Output 1
03
P2
Output 2 Polarity
Output 2 polarity, see parameter regarding “Output
1 Polarity
no
o3
Output 3
Output 3 signal type, see “Output 1
19
P3
Output 3 Polarity
Output 3 polarity, see parameter regarding “Output
1 Polarity
no
o4
Output 4
Output 4 signal type, see “Output 1
01