LOGIC “A” PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING no effect (1) no effect stops operation
reverses at
closure
no effect
stops and opens
at release (saves
CLOSE)
OPEN IN PAUSE
recharges
pause time (1)
recharges
pause time of
released leaf
stops operation no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
stops operation no effect
reverses at opening
stops and opens
at release (saves
CLOSE)
BLOCKED closes leaves closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE
disabled)
Tab. 5
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
13 FUNCTION LOGICS
Fig. 8
12 S450H BUS ENCODER WIRING
*
LEAF 1 OPENS AS FIRST AND CLOSES AS SECOND.
IF BETWEEN LEAF 1 AND 2 THERE IS NO OVERLAP,
YOU CAN SET THE LEAF DELAY TO ZERO ON THE
CONTROL BOARD.
BY REVERSING THE ENCODER WIRES YOU EXCHANGE
THE ENCODER ASSOCIATED WITH LEAF 1 AND THE
ENCODER ASSOCIATED WITH LEAF 2 AND VICE
VERSA.
LEAF 2
ONE LED ON
LEAF 1
TWO LEDS ON
LEAF 1*
LEAF 1
TWO LEDS ON
LEAF 2
ONE LED ON
LEAF 1*
REVERSING THE ENCODER WIRES
LEAF 2
LEAF 2
LEAF 1
ENCODER
LEAF 2
ENCODER
ON LEAF 1, MAKE SURE THROUGH THE BRACKET
COVER, IF WITH MOTOR AT REST DL1 AND
DL2 LEDS ARE ON
ON LEAF 2, MAKE SURE THROUGH THE BRACKET
COVER, IF WITH MOTOR AT REST BOTH DL1
LEDS ARE ON
ON LEAF 2, MAKE SURE THROUGH THE BRACKET
COVER, IF WITH MOTOR AT REST BOTH DL1
LEDS ARE ON
ON LEAF 1, MAKE SURE THROUGH THE BRACKET
COVER, IF WITH MOTOR AT REST DL1 AND
DL2 LEDS ARE ON
ENGLISH
12