E024S 16 732642 - Rev. F
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
LOGIC “EP” PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED openstheleaves
opensreleased
leaf
noeffect
(OPENdisabled)
noeffect
(OPENdisabled)
noeffect
noeffect
(OPENdisabled)
OPENING
stopsoperation
(1)
stopsoperation stopsoperation
immediately
reversesatclo-
sure
noeffect
stopsandopensat
release
(OPENstops-
savesCLOSE)
OPEN
reclosesleaves
immediately(1)
reclosesleaves
immediately
noeffect
(OPEN/CLOSE
disabled)
noeffect
noeffect
(CLOSEdisabled)
noeffect
(OPEN/CLOSEdisabled)
CLOSING stopsoperation stopsoperation stopsoperation noeffect
reversesatopening
stopsandopensat
release
(OPENstops-
savesCLOSE)
BLOCKED
restartsmovingin
oppositedirection.
Alwaysclosesafter
STOP
restartsmovingin
oppositedirection.
Alwaysclosesafter
STOP
noeffect
(OPEN/CLOSE
disabled)
noeffect
(OPENdisabled)
noeffect
(CLOSEdisabled)
noeffect
(OPENstops-
savesCLOSE)
LOGIC “E” PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED openstheleaves
opensreleased
leaf
noeffect
(OPENdisabled)
noeffect
(OPENdisabled)
noeffect
noeffect
(OPENdisabled)
OPENING
stopsoperation
(1)
stopsoperation stopsoperation
immediately
reversesat
closure
noeffect
stopsandopensatrelease
(OPENstops-savesCLOSE)
OPEN
reclosesleaves
immediately(1)
reclosesleaves
immediately
noeffect
(OPEN/CLOSE
disabled)
noeffect
noeffect
(CLOSEdisabled)
noeffect
(OPEN/CLOSEdisa-
bled)
CLOSING
reopensleaves
immediately
reopensleaves
immediately
stopsoperation noeffect
reversesatopening
stopsandopensatrelease
(OPENstops-savesCLOSE)
BLOCKED closesleaves closesleaves
noeffect
(OPEN/CLOSE
disabled)
noeffect
(OPENdisabled)
noeffect
(CLOSEdisabled)
noeffect
(OPENstops-
savesCLOSE)
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
(1)ifthecyclebeganwithOPEN-B(releasedleaf),bothleavesareactivatedatopening
LOGIC “AP PULSES
AUTOMATED SYSTEM STATUS
OPEN A OPEN B STOP FSW OP FSW CL FSW CL/OP
CLOSED
opensandcloses
afterpausetime
opensreleased
leafandcloses
afterpausetime
noeffect
(OPENdisabled)
noeffect
(OPENdisabled)
noeffect
noeffect
(OPENdisabled)
OPENING
stopsoperation
(1)
stopsoperation stopsoperation
reversesat
closure(saves
OPEN)
noeffect
stopsandopensat
release
(OPENstops-
savesCLOSE)
OPEN IN PAUSE
stopsoperation
(1)
stopsoperation stopsoperation noeffect
recharges
pausetime
(CLOSEdisabled)
recharges
pausetime
(CLOSEdisabled)
CLOSING
reopensleaves
immediately
reopensleaves
immediately
stopsoperation noeffect
reversesatopening
stopsandopensat
release
(OPENstops-
savesCLOSE)
BLOCKED closesleaves closesleaves
noeffect
(OPEN/CLOSE
disabled)
noeffect
(OPENdisabled)
noeffect
(CLOSEdisabled)
noeffect
(OPEN/CLOSEdisa-
bled)