E024S 13 732642 - Rev. F
1
2
3.9x16
11 BUS ENCODER WIRING
10 AUTOMATED SYSTEM TEST
Whenyouhavefinishedprogramming,checkifthesystemis
operatingcorrectly.Inparticular,checkifthesafetydevices
areoperatingcorrectly.
Fig.6
9.1 BATTERY KIT OF E024S ON 391 (OPTIONAL)
Thebatterykitenablesyoutoactivatetheautomatedsystem
evenintheeventofamainspowerfault.Thebatteriesare
housedinaspecificcompartmentinsidetheoperator(see
sequenceinfig.6).
Toinstall,refertothespecificinstructions.
The batteries start operating when mains
voltage fails.
E024Sisusedtocontrolbusencoders.Anyencodersconnectedtotheredbusterminalarerecognisedduringbusdevice
acquisition(chapter7.2).
Theuseofthistypeofencoderofferspreciseandconstantinformationonleafposition,guaranteeingreversemovementin
caseofobstacles.
Theencoderiscompulsoryonhydraulicoperators(S450H,S700H,S800H,S800HENC)andoptionalonelectromechanical
operators.
Leaf1 Leaf2 Leaf1Leaf2
Leaf 1 opens as first and closes as second
Leaf 1 (DL1, DL2 on) Leaf 2 (DL1 on)
S450H, 412, 413, 415, 770 , 770N
SAFECODER
Absolute encoder
DL1
DL2
DL3
DL1
DL2
DL3
S700H/S800H
Relative encoder
DL1
DL2DL3
DL1
DL2DL3
S800H ENC
Relative encoder
(It only works as a relative
encoder on E024S)
DL1
DL2
DL3
DL1
DL2
DL3
1. Connectthe2encodercablestotheBUSinput(redterminal)ontheelectronicboard.
2. EnsurethattheencoderLEDslightupasreportedinthetable.TheLEDsmustbecheckedwiththeleafstopped.
Fig.7
ENGLISH