14
ENGLISH
1
ST
LEVEL PROGRAMMING
Display Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
dF
DEFAULT:
0 Configures the parameters with DEFAULT values
corresponding to an installation with non-FAAC
operators. (see default column 0).
1 Configures the parameters with DEFAULT values
corresponding to an installation with operators
FAAC 412, 413/415, 770, 390 (see default
column 1).
2 Configures the parameters with DEFAULT values
corresponding to an installation with operators
FAAC 391 (see default column 2).
3 Configures the parameters with DEFAULT values
corresponding to an installation with operators
FAAC S700H/S800H (see default column 3.
4 Configures the parameters with DEFAULT values
corresponding to an installation with operators
FAAC 418. (see column default 4).
5 Configures the parameters with DEFAULT values
corresponding to an installation with operators
FAAC S450H (see column default 5).
CU If the CU value appears when you release
the F push-button, this means that a standard
configuration modified by push-buttons and
display was selected. If you wish to maintain this
programming, press push-button F again.
PC If the PC value appears when you release the F
push-button, this means that programming from
the PC was effected with the default password
(0000). By pressing the + and - keys, you can
load a default configuration from among
those listed above. If you wish to maintain
programming from the PC, press push-button F
again.
0
1 2 3 4 5
MO
TYPE OF MOTOR:
00 non-FAAC operators.
1 operators FAAC 412, 413/415, 770, 390.
2 operators FAAC 391.
3 operators FAAC S700H/S800H.
04 operators FAAC 418
05 operators FAAC S450H
View only parameter, cannot be modified
00 01 02 03 04 05
LO
FUNCTION LOGICS:
E Semi-automatic.
EP Semi-automatic “Step by step”.
S “Safety devices” automatic.
SA Automatic with in-pause reversing.
SP ”Step-by-step safety devices” automatic.
A 1 Automatic 1.
A Automatic.
AP Automatic “Step-by-step”.
At Automatic with timer function.
b Semi-automatic “b”.
bC Mixed (OP at impulse/CL Dead-man).
C Dead-man.
CU Custom.
Other more detailed programming
possibilities are feasible by programming
with a PC (see dedicated instructions).
E E E E E E