21
ENGLISH
Display Function
Default
0
Default
1
Default
2
Default
3
Default
4
Default
5
AS
ASSISTANCE REQUEST CYCLES COUNTER (coupled to
the next two functions):
Y = When the number of cycles settable with the
following n c and n d functions is reached, this
facility pre-flashes for 8 sec. (in addition to the pre-
flashing already set with the PF function) before
every movement.
If, from the PC, an assistance request is
set, with a number of cycles greater than
99.990, the next two functions nc and nd
will respectively show 99 and 99.
no = the following functions
nc and nd
indicate how
many cycles the system effected up to a maximum
displayable amount of 99.990.
If the number of effected cycles is greater
than 99.990, the next two functions nc
and nd will respectively show 99 and
99.
This function can be useful to set routine maintenance
or to check the effected work cycles.
no no no no no no
nc
CYCLE PROGRAMMING (THOUSANDS):
If AS = Y, the display indicates the number of the thou-
sands of cycles after which assistance is request-
ed (settable from 0 to 99).
If A S = no, the display indicates the number of the
thousands of effected cycles. The displayed val-
ue updates itself as the cycles follow, interacting
with the nd values.
If AS = no by pressing keys + and – for 5
sec., the cycles counter is reset.
00 00 00 00 00 00
nd
CYCLE PROGRAMMING (TENS):
If AS = Y, the display indicates the number of tens
of cycles after which assistance is requested
(settable from 0 to 99).
If AS = no, the display indicates the number of the tens
of effected cycles. The displayed value updates
itself as the cycles follow, interacting with the n c
values.
Example: If the system has performed 11.218,
nc = 11 and nd = 21 will be shown
00 00 00 00 00 00
M1
MOTOR 1 DRIVE (dead-man function)
Hold down push-button + opening oP
Hold down push-button - closing cL
-- -- -- -- -- --
M2
MOTOR 2 DRIVE (dead-man function)
Hold down push-button + opening oP
Hold down push-button - closing cL
-- -- -- -- -- --
St
AUTOMATED SYSTEM STATUS:
Exit from programming, storage of data and return to the automated system status view.
00 = CLOSED
01 = OPEN
02 = Idle then “OPENS
03 = Idle then “CLOSES
04 = In “PAUSE”
05 = At opening stage
06 = At closing stage
07 = FAIL SAFE in progress
08 = verification of BUS-2EASY devices in progress
09 = Pre-flashing then “OPENS
10 = Pre-flashing then “CLOSES
11 = Opening in EMERGENCY status
12 = Closing in EMERGENCY status