E1SL 37 532258 04 - Rev. B
Translation of the original instructions
ENGLISH
Errors and Warnings
(codes on grey background = warnings)
Required action (perform
RESET after the intervention)
53
CYCLES NUMBER CORRUPTED Replace the board and carry out maintenance on the system.
54
LOCK HW FAULT Perform RESET. Check the motor block.
55
PHARMACY MODE IN PROGRESS PHARMACY OPEN is in progress.
56
BATTERY OPERATION The warning remains as long as the automation operates on the battery with mains power supply down.
57
SEARCHING FOR OPENING STOP IN PROGRESS The indication remains as long as the stage is ongoing.
58
SEARCHING FOR CLOSING STOP IN PROGRESS The indication remains as long as the stage is ongoing.
59
LOCK FAULT (SURVEILLANCE KIT) Perform RESET. If the problem persists, replace the motor block.
60
MAINTENANCE REQUEST Carry out ordinary or periodic scheduled maintenance.
61
SDK EVO / LK EVO/ KS EVO FAULT
Check it is the correct device and check the SDK EVO / LK EVO/KS EVO connections. Update FW. If the
problem persists, replace the SDK EVO / LK EVO / KS EVO.
62
BATTERY CHARGER FAILURE Perform RESET. If the problem persists, replace the board.
63
INTRUSION An attempt to open the automation is in progress.
65
SETUP IN PROGRESS SETUP is in progress.
66
MOVEMENT WITH MOTOR2 IS IN PROGRESS The second Motor is in operation.
67
SLEEP
Low power mode is in progress: to prevent the emergency battery from being discharged, power to the ac-
cessories is switched off apart from to the SDK EVO.
68
SAFETIES TEST FAILED
The TEST on inputs configured as safeties has failed. In this condition, the automation moves at a slower
speed. Check that the safety detector is working. If the problem persists, replace the device.
69
DOOR OPEN SEMI-AUTOMATIC OPEN Door is open from SEMI-AUTOMATIC OPEN input.
70
BATTERY DISCHARGED The emergency battery has a low charge level.
71
INTERCOM The automation is in INTERCOM mode.
72
INTERCOM FAULT No communication between the Master and Slave nodes.
73
INTERLOCK FUNCTION ACTIVE The automation is in INTERLOCK mode.
74
INTERLOCK FUNCTION IN PROGRESS MODFUN INTERLOCK is running.
75
INTERCOM SLAVE NODE in MAINTENANCE MANUAL/LOCAL The INTERCOM board has been put in maintenance mode.
77
INTERCOM REGISTRATION IN PROGRESS The automation is the MASTER and is registering the nodes.
78
AIRSLIDE IN PROGRESS The automation is in AIRSLIDE mode.
79
INTERLEAVES IN PROGRESS The automation is in INTERLEAVES mode.
80
NON-STANDARD PROGRAMMING Non Standard configuration in use.
81
UPDATE FILES MISSING FROM USB Check for files on the USB memory device.
82
FILE WRITING ERROR Download the files to the USB storage device again.
83
DEVICE BEING UPDATED INCORRECT OR MISSING The connected device on which you are attempting to update the FW is not compatible or not connected.
84
FW UPDATE ERROR File read error. Repeat update from USB.
88
FILE READ ERROR File corrupted or not the right one, device to be updated.
90
PASSWORD ERROR Password file different to the one on the board.
91
BOARD FAILURE Replace board.
96
Microcontroller fault Replace board.
97
USB ERROR USB device not recognised, not formatted with the FAT or FAT 32 file system, or faulty.
99
BOARD DATA DELETION IN PROGRESS Wait for the data deletion procedure to finish.
101
FW FAULT SDK EVO Carry out the RESET procedure. If the error persists, replace the SDK EVO.
102
SDK EVO FAILURE Carry out the RESET procedure. If the error persists, replace the SDK EVO.
103
SDK EVOLANGUAGE LOADING ERROR Carry out the RESET procedure. If the error persists replace the SDK EVO.
104
SDK EVO FW ERROR Update the SDK EVO firmware.
105
BOARD COMMUNICATION ERROR
Check the connections. If the error persists, the communication channel of the board, the SDK EVO, or both
are damaged. Replace the board or the SDK EVO.
106
SDK EVO CONNECTED TO A BOARD THAT IS NOT RECOG-
NISED
Check the type of board.